Industrial Automation

 

Part No.

PTC 6 AF Q R GGDD E ASB

Feature
  • Input transients & surge protected.
  • Multi PIM Hot-Swappable unit with Forced Cooling
  • 230VAC Input / 24VDC/10A,12VDC/10A (N+1 Redundancy) Two set each.
  • Rugged AC / DC Converter for Industrial & Railway applications.
  • Over-voltage / Short-circuit / Over-current / Over-temp. protected.
standard (conformance)
Vibration 10 - 55Hz, 19.6m/s2(2G)
Impact 196.1m/s2 (10G), 11ms, Once each X, Y, & Z.
Input
Voltage 230VAC ± 10%, 50Hz ± 5%
Current 7.5A max.
Output

Output

24VDC/10A (N+1) O/P-1

24VDC/10A (N+1) O/P-2

Redundancy

O/P-1 -A

O/P-1 -B

O/P-2 -A

O/P -2-B

Factory Set Voltage 24VDC 24VDC 24VDC 24VDC
Current 10A 10A 10A 10A
 

 

Part No.

PTC 3 AFDD S P D C BEB

Feature
  • Convection / Force air Cooling.
  • Input Volatge AC-DC / DC-DC
  • Rugged AC-DC / DC-DC Converter for Industrial applications.
  • Over-voltage/Short-circuit/Over-current/Over-temp. Protected.
standard (conformance)
EMI & EMC As per CISPR 22
Environmental As per QM333 Class B Except Temp.
Input
VAC I/P Voltage 165VAC - 270VAC ( 230VAC nominal), 1 Phase 50Hz
VDC I/P Voltage -36VDC to -70VDC (-48VDC Nominal)
Output
Voltage 12VDC
Current 12.5A
Power 150W
 

 

Part No.

1KW DC/DC SINGLE OUTPUT

Feature
  • Shock & vibration tested
  • 48VDC input / 48VDC output.
  • Dual Redundant Unit with Forced air Cooling.
  • Fast transients & reverse polarity protection.
  • Rugged DC/DC converter for Industrial applications.
  • Overvoltage/short circuit/overcurrent/over-temp. protected.
standard
Vibration 10 - 55Hz, 19.6m/s2(2G)
Safety standards Design conforms to UL60950-1
Input
Voltage -48VDC (-40 to -60VDC)
Current 14A max.
Output
Voltage 48VDC
Current 10A
Power 480W+480W
 

 

Part No.

4000W AC / DC SINGLE OUTPUT DUAL REDUNDANT PSU

Feature
  • Forced Cooling.
  • 3Φ 415VAC- 4 wire input / 54-72 VDC/25A Redundant Output.
  • Input transients & reverse polarity protection.
  • Rugged 3Φ AC / DC Converter for Industrial applications
  • Over-voltage / short-circuit / Over-current / Over-temp. protected.
Standard (conformance)
Vibration 10 - 55Hz, 19.6m/s2 (2G)
Impact 196.1m/s2 (20G), 11ms, Once each X, Y, & Z
Input
Voltage Dual Input -3Φ 415VAC ± 10%,4 wire 50Hz ±􀀃5%
Current 10A max.
Output
Factory Set Voltage 60VDC
Current 25A
Power 1800W Dual Redundant
 

 

Part No.

1K1 H I-24 R
1100W AC-DC/DC-DC HEXA OUTPUT

Feature
  • Force air Cooling.
  • Input Volatge 415V AC ±10%, 50Hz ±5%, 3Ø, 4 wire.
  • Rugged AC-DC Converter for Industrial applications.
  • Over-voltage/Over-current/Over-temp. Protected.
Standards
Safty and Noise UL-60950-1, EN60950-1, EN50178, EN55011-B,
Regulations EN55022-B
Safty and Noise 10-55Hz, 49.0m/s² (2G), 3minutes period, 60minutes each alog X, Y and Z axis
Impact 196.1m/s2 (2G), 11ms, once each along, X, Y, and Z axis
Input
Input Voltage 415V AC ±10%, 50Hz ±5%, 3Ø, 4 wire.
Power(KVA) 49 KVA
Current 72 A Max Each Phase
Output
Voltage 300VDC
V Adj 160-320VDC
Current 0-135A
Power 43.2 KW Max